[1] Weng MK, Brooks RB, Glowicz J, et al. Outbreak investigation of Pseudomonas aeruginosa infections in a neonatal intensive care unit. Am J Infect Control. 2019;47(9):1148-1150. doi:10.1016/j.ajic.2019.03.009
[2] Chan PC, Huang LM, Lin HC, et al. Control of an outbreak of pandrug-resistant Acinetobacter baumannii colonization and infection in a neonatal intensive care unit. Infect Control Hosp Epidemiol. 2007;28(4):423-429. doi:10.1086/513120
[3] Gramatniece A, Silamikelis I, Zahare I, et al. Control of Acinetobacter baumannii outbreak in the neonatal intensive care unit in Latvia: whole-genome sequencing powered investigation and closure of the ward. Antimicrob Resist Infect Control. 2019;8:84. Published 2019 May 22. doi:10.1186/s13756-019-0537-z
[4] Yiallouros PK, Papadouri T, Karaoli C, et al. First outbreak of nosocomial Legionella infection in term neonates caused by a cold mist ultrasonic humidifier. Clin Infect Dis. 2013;57(1):48-56. doi:10.1093/cid/cit176
[5] Verweij PE, Meis JF, Christmann V, et al. Nosocomial outbreak of colonization and infection with Stenotrophomonas maltophilia in preterm infants associated with contaminated tap water. Epidemiol Infect. 1998;120(3):251-256. doi:10.1017/s0950268898008735
[6] European Centre for Disease Prevention and Control. Carbapenem-resistant Enterobacterales, third update – 3 February 2025. ECDC: Stockholm; 2025. Link to Full Issue
[7] Kaul CM, Chan J, Phillips MS. Mitigation of nontuberculous mycobacteria in hospital water: challenges for infection prevention. Curr Opin Infect Dis. 2022;35(4):330-338. doi:10.1097/QCO.0000000000000844
[8] Ceri H, Olson ME, Stremick C, Read RR, Morck D, Buret A. 1999.The Calgary Biofilm Device: New Technology for Rapid Determination of Antibiotic Susceptibilities of Bacterial Biofilms. J Clin Microbiol 37: https://doi.org/10.1128/jcm.37.6.1771-1776.1999
[9] Trautmann M, Halder S, Hoegel J, Royer H, Haller M. Point-of-use water filtration reduces endemic Pseudomonas aeruginosa infections on a surgical intensive care unit. Am J Infect Control. 2008;36(6):421-429. doi:10.1016/j.ajic.2007.09.012
[10] Barna Z, Antmann K, Pászti J, et al. Infection control by point-of-use water filtration in an intensive care unit – a Hungarian case study. J Water Health. 2014;12(4):858-867. doi:10.2166/wh.2014.052
[11] Parkinson J, Baron JL, Hall B, et al. Point-of-use filters for prevention of health care-acquired Legionnaires’ disease: Field evaluation of a new filter product and literature review. Am J Infect Control. 2020;48(2):132-138. doi:10.1016/j.ajic.2019.09.006
[12] Sasahara T, Ogawa M, Fujimura I, Ae R, Kosami K, Morisawa Y. Efficacy and Effectiveness of Showerheads Attached with Point-of-use (POU) Filter Capsules in Preventing Waterborne Diseases in a Japanese Hospital. Biocontrol Sci. 2020;25(4):223-230. doi:10.4265/bio.25.223
[13] Demirjian A, Lucas CE, Garrison LE, et al. The importance of clinical surveillance in detecting legionnaires’ disease outbreaks: a large outbreak in a hospital with a Legionella disinfection system-Pennsylvania, 2011-2012. Clin Infect Dis. 2015;60(11):1596-1602. doi:10.1093/cid/civ153
[14] Kolmos HJ, Thuesen B, Nielsen SV, Lohmann M, Kristoffersen K, Rosdahl VT. Outbreak of infection in a burns unit due to Pseudomonas aeruginosa originating from contaminated tubing used for irrigation of patients. J Hosp Infect. 1993 May;24(1):11-21. doi: 10.1016/0195-6701(93)90085-e. PMID: 8101198.
[15] Rogues AM, et al. Tap water as a source of Pseudomonas aeruginosa in a medical ICU setting. Journal of Hospital Infection, 2007; 67(1):72-78. [https://www.journalofhospitalinfection.com/article/S0195-6701(07)00209-5/abstract]
[16] Ricci P, Graldi P, Galli S, Vinelli N. Pseudomonas infections and water treatment in a haematology ward. 30th Congresso Nationale L’Azienda Sanitaria, Sorrento, Italy, 2004, abstract no. 164.1
[17] ASHRAE 514 Standard: [https://www.ashrae.org/technical-resources/standards-and-guidelines/guidance-for-water-system-risk-management]