• Gold-coated PET membrane

    for particle and microplastic analysis

    Gold-coated membranes are used for the identification and characterization of micro- and nanoparticles in pharmaceutical fluids and chemical auxiliary agents as well as in foods and cosmetics. In pharmaceutical production, the freedom of a product from particles and the monitoring of a product’s particle content are fundamental requirements.

    A gold-coated membrane held by a pair of tweezers

    Product purity for human protection

    Contamination during manufacturing occurs naturally due to people and machines. Contamination due to solid materials such as particles, dust and organisms, or due to materials in liquid and gaseous forms such as product residues and aerosols, must be detected and evaluated. In addition, contamination can be created by packaging and production equipment. Checking the end product, often too late, is complex and expensive. Particle testing should therefore be integrated into the production process at an early stage to guarantee the purity of the product and to protect people.

    The polyester membranes may also be used in technical cleanliness testing of functionally relevant automotive parts (particle contamination) in accordance with ISO 16232 and VDA 19. Particles are removed from automotive parts by methods such as sluicing with testing fluid. The testing fluid is then filtered through the i3 TrackPor P membranes which are prepared for examination under a light microscope.

    High stability over a long filtration period

    The i3 TrackPor P membranes feature a particularly smooth even surface. The polyester membrane (PET) with a 100/0 nm gold layer makes it possible to filter out all organic and inorganic particles. The i3 TrackPor P membranes are stable in a liquid medium for longer filtration periods. They provide optimal reflection in Fourier transform infrared (FTIR) microscopy and make a suitable conductive substrate for scanning electron microscope imaging (EDX/WDX).

    To stabilize the gold-coated polyester membrane in the filtration and analysis phase, the filters can be used equipped with an aluminum ring.

    i3 TrackPor P

    A gold-coated membrane held by a pair of tweezers
    Request an offer

    Our gold-coated polyester membrane (PET) i3 TrackPor P can be purchased in all standard diameters from 13 to 47 millimeters and pore sizes from 0.8 to 5 micrometers.

    Special customizations are also possible on request.

    • Reflective gold layer for optimal illumination intensity

    • Stable over a long filtration period

    • Suitable for the entire pH scale

    • Highest product quality for maximum reliability

    Attribute
    Pore size* 0.05 µm 0.8 µm 3.0 µm 5.0 µm
    Membrane material Polyester
    Poren density (cm-2) 6.00 E + 08 4.00 E + 07 3.00 E + 06 4.00 E + 05
    Membrane thickness (µm) 23 22 20 19
    Gold coating** (nm) 100/0
    Diameter (mm) 13 / 25 / 30 / 37 / 45 / 47

    *other pore sizes available on request
    **top/bottom

    i3 TrackPor R

    Angled view of a gold-coated membrane assembled in an aluminum ring
    Request an offer

    Our gold-coated polyester membrane (PET) i3 TrackPor R is additionally framed in an aluminum ring. This makes it much easier to handle. The membrane cannot be scratched or bent, and it is easier to use in vacuum filtration.

    Special customizations are also possible on request.

    • Reflective gold layer for optimal illumination intensity

    • Stable over a long filtration period

    • Suitable for the entire pH scale

    • In an aluminum ring for easier handling

    Attribute
    Pore size* 0.8 µm 3.0 µm 5.0 µm
    Membrane material Polyester
    Pore density (cm-2) 4.00 E + 07 3.00 E + 06 4.00 E + 05
    Membrane thickness (µm) 22 20 19
    Gold coating** (nm) 100/0
    Diameter (mm) 30

    *other pore sizes available on request
    **top/bottom

    Attribute
    Weight 1.5 g
    Height 1.9 mm
    Diameter 32 mm
    Material Aluminum
    A gold-coated membrane held by a hand with a pair of tweezers
    A hand with orange glove holding a gold-coated membrane assembled in an aluminum ring
    Close-up of several gold-coated membranes in the punching machine with tweezers detaching a membrane
    Close-up of colorful microplastic particles on the surface of a gold-coated membrane
    Microscope view of the surface of a gold-coated track-etched membrane with clearly visible pores
    Image composition consisting of two i3 TrackPor M air monitor cassettes and the membranes i3 TrackPor, i3 TrackPor R and i3 TrackPor PAR

    Order your free sample pack!

    Request our membrane samples here free of charge and without obligation to see the high quality and easy handling for yourself.

    Particle & microplastic analysis

    with i3 TrackPor P & i3 TrackPor R

    Discover our videos for particle analysis and microplastic analysis with the gold-coated PET membranes i3 TrackPor P and i3 TrackPor R.

    Microplastics analysis with i3 TrackPor P track-etched gold-coated membranes
    Track-etched membranes for particle analysis
    Particle analysis with i3 membranes – individual solutions for your challenges!
    Particle analysis with i3 TrackPor track-etched gold-coated membranes